The reactor at Diablo Canyon nuclear power plant in San Luis Obispo operated for a year and a half with some emergency systems disabled, according to a 2010 safety review by the federal Nuclear Regulatory Commission.
The incident was one of 14 “near-misses” the NRC uncovered in its inspections of nuclear power plants where problems had been occurring. An analysis by the group Union of Concerned Scientists concluded that “many of these significant events occurred because reactor owners, and often the NRC, tolerated known safety problems.” The NRC found a range of problems at the 14 plants, including poor design, equipment failure, poor training and human error.
Source: Los Angeles Times
The incident was one of 14 “near-misses” the NRC uncovered in its inspections of nuclear power plants where problems had been occurring. An analysis by the group Union of Concerned Scientists concluded that “many of these significant events occurred because reactor owners, and often the NRC, tolerated known safety problems.” The NRC found a range of problems at the 14 plants, including poor design, equipment failure, poor training and human error.
Source: Los Angeles Times